- A test has been performed using a scaled aircraft wing section in an icing tunnel facility. The model had an electro-thermal ice protection system installed. The tests performed considered both anti-icing and de-icing modes of operation. The results have been assessed using numerical codes and the effect of model scaling has been considered. The non-scaled skin thickness of the model was found to modify the predicted behaviour of a full-scale installation, predominantly due to lateral conduction effects. The extent of this has been assessed and recommendations are made as to the performance that may be expected at full-scale.
- Pages
- 10
- Citation
- Barley, S., "Evaluation of Small Scale Icing Tunnel Test Results," SAE Technical Paper 2007-01-3328, 2007, https://doi.org/10.4271/2007-01-3328.