An Evaluation of the SAE Recommended Design Changes to the Hybrid III Dummy Hip Joint

950665

02/01/1995

Event
International Congress & Exposition
Authors Abstract
Content
The SAE Large Male and Small Female Dummy Task Group has recommended a change to the Hybrid III dummy hip joint. This change was made because of a non-biofidelic interference in the current design that can influence chest accelerations. The modifications include a new femur casting shaft design and the addition of an elastomeric stop to the top of the casting. Static testing and Hyge sled tests were done to evaluate the modifications. Based on the results, the new design satisfied the requirements set by the SAE task group and reduced the influence of hip joint characteristics on chest accelerations.
Meta TagsDetails
DOI
https://doi.org/10.4271/950665
Pages
14
Citation
Abramoski, E., Warmann, K., Feustel, J., Wilson, P. et al., "An Evaluation of the SAE Recommended Design Changes to the Hybrid III Dummy Hip Joint," SAE Technical Paper 950665, 1995, https://doi.org/10.4271/950665.
Additional Details
Publisher
Published
Feb 1, 1995