End-To-End Protection for SIL3 Requirements in a FlexRay Communication System

2008-01-0112

04/14/2008

Authors
Abstract
Content
This paper proposes end-to-end protection mechanisms to be added to a generic FlexRay network in order to achieve fault detection and integrity levels sufficient for a SIL3 fail safe communication system. The mechanisms are derived from the random hardware failure modes to be considered for communication controllers according to IEC 61508. Mechanisms provided by the FlexRay protocol are pointed out. Additional features necessary to fulfil the requirements are discussed. It is shown how to calculate the failure rate probabilities of the CRC used as a safety code with respect to EN 50159.
Meta TagsDetails
DOI
https://doi.org/10.4271/2008-01-0112
Pages
8
Citation
Gstöttenbauer, B., Stöger, G., Fazely, S., Kalhammer, M. et al., "End-To-End Protection for SIL3 Requirements in a FlexRay Communication System," SAE Technical Paper 2008-01-0112, 2008, https://doi.org/10.4271/2008-01-0112.
Additional Details
Publisher
Published
Apr 14, 2008
Product Code
2008-01-0112
Content Type
Technical Paper
Language