Electromechanical vibration problem in railway traction system arises from that mechanical excitation transits through the speed feedback path, leading to a decrease in operational stability and deterioration of torque quality. Frequency sweep analysis reveals another phenomenon, that is, the closed-loop harmonic frequency falls at 67.83 Hz, which is much lower than the resonant frequency of the open-loop mechanical mode 117.43 Hz. The reason for frequency bias phenomenon is that the dynamic coupling between the speed control system and mechanical subsystem has weakened the equivalent stiffness. Electromechanical problem can be solved by coupling active damping and notch filter. Active damping provides wide-band damping to low frequency dynamics, while the notch filter is accurate at the 67.83 Hz peak, which is the resonant frequency of the closed-loop harmonic mode. Parameter sweep analysis shows that 0.5 N·m·s/rad is a good choice for active damping coefficient, and the notch filter inhibition ratio takes 0.5. Compared with traditional PI control, the phase margin has increased from 35.2° to 65.5°. The torque ripple has dropped by 78.8%, which is the most significant improvement. Combined score has increased by 88.5% in which 15.4% gain is brought by non-linear gain contributed by non-linear addition. The strategy works reliably in the range of operation from 600 to 800 rpm. Also, it can handle ±30% inertia change and ±20% stiffness variation, even in the worst operating condition, with a phase margin of 61.2°. For practical applications, every control cycle consumes only 15 floating point operations, which is within the capability of modern DSPs.