The Effect of Fouling on the Performance of Finned Tube Heat Exchanger

971806

5/19/1997

Authors
Abstract
Content
This paper presents an investigation of the effect of fouling by considering a tube and plate fin geometry for which performance characteristics are well defined.
By matching a particular heat exchanger to a given fan it can be shown that the air-side heat transfer coefficient increases as the air-side passages become progressively blocked, reaching a maximum close to the fully blocked condition.
For moderate fouling this increase largely compensates for the change in mean temperature difference brought about by the variation in air flow rate, giving an overall performance very close to that for the clean condition.
Meta TagsDetails
DOI
https://doi.org/10.4271/971806
Citation
Sherwin, K., "The Effect of Fouling on the Performance of Finned Tube Heat Exchanger," 1995 Vehicle Thermal Management Systems Conference and Exhibition, London, United Kingdom, May 9, 1995, https://doi.org/10.4271/971806.
Additional Details
Publisher
Published
5/19/1997
Product Code
971806
Content Type
Technical Paper
Language
English