The Effect of Changes in Ambient and Coolant Radiator Inlet Temperatures and Coolant Flowrate on Specific Dissipation

2000-01-0579

3/6/2000

Authors
Abstract
Content
In this paper, a theoretical model for the calculation of Specific Dissipation (SD) was developed. Based on the model, the effect of ambient and coolant radiator inlet temperatures on SD has been predicted.
Results indicate that the effect of ambient and coolant inlet temperature variation on SD is small (less than 2%) when ambient temperature varies between 10 and 50°C and coolant radiator inlet temperature between 60 and 120°C.
The effect of coolant flowrate on SD is larger if there is a larger flowrate variation. Experimental results indicate that a 1 % variation at 1.0 L/s will cause about ±0.6% SD variation. Therefore the flowrate should be carefully controlled.
Meta TagsDetails
DOI
https://doi.org/10.4271/2000-01-0579
Citation
Lin, C., Saunders, J., and Watkins, S., "The Effect of Changes in Ambient and Coolant Radiator Inlet Temperatures and Coolant Flowrate on Specific Dissipation," SAE 2000 World Congress, Detroit, Michigan, United States, March 6, 2000, https://doi.org/10.4271/2000-01-0579.
Additional Details
Publisher
Published
3/6/2000
Product Code
2000-01-0579
Content Type
Technical Paper
Language
English