Dynamic Spot Weld Testing
2009-01-0032
04/20/2009
- Event
- Content
- Static and dynamic strength tests were performed on spot welded specimens made of dual-phase (DP) 780 and mild steels (DQSK). Lap-shear (LS) and cross-tension (CT) as well as a new mixed mode specimen were studied using MTS hydraulic universal testing machine for static tests and drop weight tower for dynamic tests. Three weld nugget sizes were made for each steel and CT and LS. DP780 with one weld size was also tested in mixed mode. Load and displacement as functions of time and fracture mode of the spot welds were recorded. Representative data are reported in this paper.
- Pages
- 11
- Citation
- Chao, Y., Kim, Y., Feng, Z., Simunovic, S. et al., "Dynamic Spot Weld Testing," SAE Technical Paper 2009-01-0032, 2009, https://doi.org/10.4271/2009-01-0032.