Dynamic Fatigue Data for Cordierite Ceramic Wall-Flow Diesel Filters

910135

2/1/1991

Authors
Abstract
Content
The dynamic fatigue data for two different cordierite ceramic wall-flow diesel filter compositions, EX-54 and EX-66, are obtained at 200° and 400°C using the 4-point bend test. These compositions offer larger mean pore size and experience lower pressure drop than the EX-47 composition, and hence are more desirable for certain applications. Their fatigue behavior in the operating temperature range is found to be equivalent or superior to that of EX-47 composition which helps promote filter durability. The fatigue data are used to arrive at a safe allowable stress, which would ensure the required 290K vehicle mile durability. The paper also discusses the impact of mean pore size on high temperature strength and fatigue properties and their effect on filter durability.
Meta TagsDetails
DOI
https://doi.org/10.4271/910135
Pages
15
Citation
Gulati, S., and Sherwood, D., "Dynamic Fatigue Data for Cordierite Ceramic Wall-Flow Diesel Filters," SAE Technical Paper 910135, 1991, https://doi.org/10.4271/910135.
Additional Details
Publisher
Published
2/1/1991
Product Code
910135
Content Type
Technical Paper
Language
English