Design and Testing of Rollover Protective Structures in Accordance with SAE J395
710509
02/01/1971
- Event
- Content
- Plastic analysis type of analytical calculations are included in this paper as a guide for designers to size Rollover Protective Structures to meet SAE J-395. Basic design considerations are given including material selection, brittle failures, local buckling, and allowable deflections.
- Pages
- 8
- Citation