Deposit-Induced Runaway Surface Ignition

620243

1/1/1962

Authors
Abstract
Content
Deposit induced runaway surface ignition may be avoided by proper engine design and maintenance, and in many cases by controlling the quantity of lubricant ash consumed by the engine. This can be done by maintaining good oil control for minimum engine wear and maximum cleanliness. The paper examines theories as to how deposit induced runaway surface ignition occurs, and reports the results of tests on truck and passenger car engines, and a single cylinder COT engine. Results indicate that deposit induced runaway surface ignition is affected by the type of combustion chamber deposits made by the fuel lubricant combination, by the deposit heating characteristics of the fuel and air mixture, and by the hot spot characteristics of the fuel air charge.
Meta TagsDetails
DOI
https://doi.org/10.4271/620243
Citation
Scott, L., Ryan, J., and Baker, J., "Deposit-Induced Runaway Surface Ignition," Pre-1964 SAE Technical Papers, Warrendale, Pennsylvania, United States, January 1, 1906, https://doi.org/10.4271/620243.
Additional Details
Publisher
Published
1/1/1962
Product Code
620243
Content Type
Technical Paper
Language
English