Deleterious Effects of Non-Condensible Gas During Capillary Pumped Loop Startup

941408

06/01/1994

Authors
Abstract
Content
Deprimes occuring in capillary pumped loops (CPLs) with small-diameter evaporator pumps (≤ 16 mm) were examined analytically and experimentally. The proposed deprime mechanism advanced by this paper is nucleation of a pressurized vapor bubble that can blow through the evaporator wick and lead to immediate CPL deprime or unstable operation with a likelihood of deprime at a later time. This failure mechanism is exacerbated by the presence of a non-condensible gas species like hydrogen in the ammonia working fluid. Use of a robust startup evaporator to empty the normal vapor spaces of the remaining CPL evaporators prior to startup is identified as the most effective method for obviating this failure mechanism and ensuring reliable CPL operation.
Meta TagsDetails
DOI
https://doi.org/10.4271/941408
Pages
13
Citation
Antoniuk, D., and Pohner, J., "Deleterious Effects of Non-Condensible Gas During Capillary Pumped Loop Startup," SAE Technical Paper 941408, 1994, https://doi.org/10.4271/941408.
Additional Details
Publisher
Published
Jun 1, 1994
Product Code
941408
Content Type
Technical Paper
Language