Coupling of Transient Analysis of Thermal Flow and Thermal Stress for T Pipe
2006-01-0589
04/03/2006
- Event
- Content
- Fluid Structure Interface (FSI) analyses were fast in development during recent years with the constantly advancing progress of computer technology. MpCCI (Mesh based parallel Code Coupling Interface) is a typical product of FSI. MpCCI has been developed at the Fraunhofer-Institute SCAI in order to provide an application-independent interface for the coupling of different simulation codes. Although FSI includes both flow induced displacement and thermal flow induced thermal stress, latter has received less attention.In this paper, temperature results of a transient thermal fluid analysis in a T pipe are used as loads for a nonlinear plastic thermal stress analysis of the pipe. In the nonlinear plastic analysis, linear proximity is used for both plastic region and elastic region. That is to say, 2-line kinematicl hardening law is used to express the stress strain characteristic of the pipe. At the same time, different numbers of load are used and the results are compared.
- Pages
- 10
- Citation
- Fan, Q., "Coupling of Transient Analysis of Thermal Flow and Thermal Stress for T Pipe," SAE Technical Paper 2006-01-0589, 2006, https://doi.org/10.4271/2006-01-0589.