CORRELATION BETWEEN LABORATORY AND ENGINE PERFORMANCE OF SYNTHETIC TURBINE LUBRICANTS

560243

01/01/1956

Event
Pre-1964 SAE Technical Papers
Authors Abstract
Content
Correlation between laboratory and engine test results is discussed for seven (7) MIL-L-7808 type synthetic gas turbine oils, of varying engine performance. Improved correlation of these test results is needed to guide researchers in development of new and improved oils and because of the high cost and time of engine testing. Many present laboratory tests fall in the “go-no go” category or are meaningless in regards to predicting engine performance. Generally, best correlation is obtained where tests are conducted under simulated engine operating conditions.
Meta TagsDetails
DOI
https://doi.org/10.4271/560243
Pages
19
Citation
DAVIDSON, T., and WAY, J., "CORRELATION BETWEEN LABORATORY AND ENGINE PERFORMANCE OF SYNTHETIC TURBINE LUBRICANTS," SAE Technical Paper 560243, 1956, https://doi.org/10.4271/560243.
Additional Details
Publisher
Published
Jan 1, 1956
Product Code
560243
Content Type
Technical Paper
Language
English