Condensation Simulation for ECU Package

2004-01-1696

03/08/2004

Event
SAE 2004 World Congress & Exhibition
Authors Abstract
Content
Up to now, while automobile electric packages have demanded the high density for small and light products, electric leaks, which have occurred due to condensation, have been a major problem. To prevent any electric leaks, a conformal coating on the electric parts (ex. ECU: Electronic Control Unit) has been needed, but in general the design rules of the conformal coating (ex. Application area) is vague. Therefore, DENSO demands to clear the design rules of conformal coating electric package for higher reliability.
To meet the demand, DENSO has developed a condensation simulation method using CAE that can show the occurrence condition of condensation fast and accurately. In the result, DENSO has been able to get the design rules where to need the conformal coating in the electric package for automobiles.
Meta TagsDetails
DOI
https://doi.org/10.4271/2004-01-1696
Pages
11
Citation
Aoki, T., Okamoto, S., Ina, O., Sugiura, A. et al., "Condensation Simulation for ECU Package," SAE Technical Paper 2004-01-1696, 2004, https://doi.org/10.4271/2004-01-1696.
Additional Details
Publisher
Published
Mar 8, 2004
Product Code
2004-01-1696
Content Type
Technical Paper
Language
English