Comparisons of Measured Drop Sizes and Velocities in a Transient Fuel Spray with Stability Criteria and Computed PDF's

910179

02/01/1991

Event
International Congress & Exposition
Authors Abstract
Content
Two sets of comparisons were made in an attempt to provide a mechanism for understanding the behavior of transient sprays. First, detailed measurements of drop size and velocity in a transient spray were compared to established stability criteria for different droplet breakup mechanisms, specifically criteria for bag breakup and boundary layer stripping. Then, probability-density-functions were determined from the experimental data and compared, where appropriate, to different computed distributions (such as the Chi-square or log-hyperbolic distributions).
Comparison with the stability criteria indicates that the a majority of droplets in the spray are susceptible to both breakup mechanisms near the injector tip. However, downstream, the spray appears to stabilize and any redistribution of droplet size must apparently be a result of collisions.
The experimentally-determined PDF's for size and velocity are functions of both position and time in the spray. Comparisons with computed PDF's show best agreement with the data for the multiparameter-dependent distributions, such as the chi-square or log-hyperbolic distributions.
Meta TagsDetails
DOI
https://doi.org/10.4271/910179
Pages
16
Citation
Koo, J., and Martin, J., "Comparisons of Measured Drop Sizes and Velocities in a Transient Fuel Spray with Stability Criteria and Computed PDF's," SAE Technical Paper 910179, 1991, https://doi.org/10.4271/910179.
Additional Details
Publisher
Published
Feb 1, 1991
Product Code
910179
Content Type
Technical Paper
Language
English