Closed Loop Environment Testing of an Air Regenerative System for ECLSS Application

981718

07/13/1998

Event
International Conference On Environmental Systems
Authors Abstract
Content
Improvement of an air revitalization technology is one of the key elements for ECLSS (Environment Control and Life Support System) in development and operation of human space systems. The paper summarizes, as a validation of off-gases “removal” technique, the actual 24hr-continuous operation testing under closed environment. The analysis focuses on the removal characteristics with low CO2 (Carbon Dioxide) concentration. A preliminary closed-loop test of CO2 “reduction” technique was conducted as well. The evaluation includes the data acquisition and analysis of CO2 Reduction Processor which employ Sabatier-reaction and air-cooling. And finally the paper addresses the key issues to further improve this air revitalization system.
Meta TagsDetails
DOI
https://doi.org/10.4271/981718
Pages
8
Citation
Yoshioka, N., and Shimoda, T., "Closed Loop Environment Testing of an Air Regenerative System for ECLSS Application," SAE Technical Paper 981718, 1998, https://doi.org/10.4271/981718.
Additional Details
Publisher
Published
Jul 13, 1998
Product Code
981718
Content Type
Technical Paper
Language
English