Closed-Loop Air-Fuel Ratio Control Using Forced Air-Fuel Ratio Modulation

980041

02/23/1998

Event
International Congress & Exposition
Authors Abstract
Content
An air-to-fuel ratio (A/F) modulation scheme is presented in which a linear feedback signal is generated from a heated exhaust gas oxygen (EGO) sensor. In this scheme, the engine A/F is modulated with a triangular waveform, and the mean value of the EGO output is obtained using a rolling average filter. The resulting output is linearly related to the exhaust A/F, and is used to provide closed-loop lean A/F operation following a cold start to enhance catalyst light-off and minimize vehicle exhaust emissions. Some engine-dynamometer results obtained using the method are presented.
Meta TagsDetails
DOI
https://doi.org/10.4271/980041
Pages
8
Citation
Reed, D., Hamburg, D., and Samimy, B., "Closed-Loop Air-Fuel Ratio Control Using Forced Air-Fuel Ratio Modulation," SAE Technical Paper 980041, 1998, https://doi.org/10.4271/980041.
Additional Details
Publisher
Published
Feb 23, 1998
Product Code
980041
Content Type
Technical Paper
Language
English