Characterization of a Multiple-Evaporator Capillary Pumped Loop

2005-01-2884

7/11/2005

Authors
Abstract
Content
The current work addresses efforts to characterize multiple-evaporator capillary pumped loops. Both experimental and analytical approaches were used to predict performance of parallel evaporators and corresponding effects from adjacent operating evaporators. The effects of low and high power dissipation and the distribution of powers among the evaporators were tested. Additionally, a pressure balance model is given where the maximum heat transfer capacity for an evaporator operating under a multi-evaporator condition is determined based on pressure distribution throughout the loop. The model and experiment comparisons demonstrated how the heat load distribution among evaporators affects the maximum capillary limit for individual evaporators operating in a multiple evaporator mode.
Meta TagsDetails
DOI
https://doi.org/10.4271/2005-01-2884
Pages
11
Citation
Muller, J., Ochterbeck, J., Perez, J., and Rogers, P., "Characterization of a Multiple-Evaporator Capillary Pumped Loop," SAE Technical Paper 2005-01-2884, 2005, https://doi.org/10.4271/2005-01-2884.
Additional Details
Publisher
Published
7/11/2005
Product Code
2005-01-2884
Content Type
Technical Paper
Language