Characteristics of PMHS Lumbar Motion Segments in Lateral Shear
2005-22-0017
11/09/2005
- Event
- Content
- The purpose of this study was to determine the characteristics of eighteen lumbar spine motion segments subjected to lateral shear forces under quasi-static (0.5 mm/s) and dynamic (500 mm/s) test conditions. The quasi-static test was also performed on the lumbar spine of a side impact anthropomorphic test device, the EuroSID-2 (ES-2). In the quasi-static tests, the maximum force before disc-endplate separation in the PMHS lumbar motion segments was 1850 ± 612 N, while the average linear stiffness of PMHS lumbar motion segments was 323 ± 126 N/mm. There was a statistically significant difference between the quasi-static (1850 ± 612 N) and dynamic (2616 ± 1151 N) maximum shear forces. The ES-2 lumbar spine (149 N/mm) was more compliant than the PMHS lumbar segments under the quasi-static test condition.
- Pages
- 14
- Citation
- Sundararajan, S., Prasad, P., Rouhana, S., Demetropoulos, C. et al., "Characteristics of PMHS Lumbar Motion Segments in Lateral Shear," SAE Technical Paper 2005-22-0017, 2005, https://doi.org/10.4271/2005-22-0017.