Automatic ECU-Calibration - An Alternative to Conventional Methods

930395

03/01/1993

Event
International Congress & Exposition
Authors Abstract
Content
Due to increasing complexity of engine electronic systems, there is a demand to handle the often more than 10,000 calibration data automatically. Establishing optimized start of injection and EGR tables of a TC DI Diesel engine by conventional methods takes about two weeks of intensive calibration work. By automatic map calibration, this task can be handled in less than 20 hours automatically, with no staff required during optimization. The benefits of automatic calibration therefore are reduced costs and faster response to any changes in parameters, even with complex multidimensional engine calibration problems.
The paper describes the optimization method as well as the experimental work on the test stand that produces the results.
Meta TagsDetails
DOI
https://doi.org/10.4271/930395
Pages
14
Citation
Kampelmühler, F., Paulitsch, R., and Gschweitl, K., "Automatic ECU-Calibration - An Alternative to Conventional Methods," SAE Technical Paper 930395, 1993, https://doi.org/10.4271/930395.
Additional Details
Publisher
Published
Mar 1, 1993
Product Code
930395
Content Type
Technical Paper
Language
English