Automatic Control of Electronic Actuators for an Optimized Engine Cooling Thermal Management

2001-01-1758

05/14/2001

Event
Vehicle Thermal Management Systems Conference & Exposition
Authors Abstract
Content
The main objectives of new technologies for internal-combustion engine are lower consumption, pollutant reduction and comfort passenger increase. To reach these objectives, we have adopted for engine thermal management two strategies: quicker rise temperature during the cold start and higher engine temperature for part load. To satisfy these criteria, we have modified the classic cooling loop. An electric water pump, an electric water valve and variable speed fan system are the new actuators automatically controlled by electronic calculator. This concept allows to obtain a warm-up time reduced by 50% and 2 to 3% fuel economy on the European cycle.
Meta TagsDetails
DOI
https://doi.org/10.4271/2001-01-1758
Pages
9
Citation
Choukroun, A., and Chanfreau, M., "Automatic Control of Electronic Actuators for an Optimized Engine Cooling Thermal Management," SAE Technical Paper 2001-01-1758, 2001, https://doi.org/10.4271/2001-01-1758.
Additional Details
Publisher
Published
May 14, 2001
Product Code
2001-01-1758
Content Type
Technical Paper
Language
English