Aperiodicity Correction for Rotor Tip Vortex Measurements
VFS-F67-000308
5/3/2011
- Content
-
The initial roll-up of a tip vortex trailing from a model-scale, hovering rotor was measured using particle image velocimetry. The unique feature of the measurements was that a mi- croscope was attached to the camera to allow much higher spatial resolution than hither to possible. This also posed some unique challenges. In particular, the existing methodologies to correct for aperiodicity in the tip vortex locations could not be easily extended to the present measurements. The difficulty stemmed from the inability to accurately determine the vortex center, which is a prerequisite for the correction procedure. A new method is proposed for determining the vortex center, as well as the vortex core properties, using a least-squares fit approach. This approach has the obvious advantage that the properties are derived from not just a few points near the vortex core, but from a much larger area of ow measurements. Results clearly demonstrate the advantage in the form of reduced variation in the estimated core properties, and also the self-consistent results obtained using three different aperiodicity correction methods.
- Citation
- Ramasamy, M., Paetzell, R., and Bhagwat, M., "Aperiodicity Correction for Rotor Tip Vortex Measurements," Forum 67 - Virginia Beach, Virginia 2011, Virginia Beach, VA, May 3, 2011, https://doi.org/10.4050/VFS-F67-000308.