Analytical Methods to Predict Liquid Congealing in Ram Air Heat Exchangers During Cold Operation
891439
7/1/1989
- Content
- RAM AIR HEAT EXCHANGERS used to cool liquids such as lube oils or Ethylene-Glycol/water solutions can be subject to congealing in very cold ambients, resulting in a loss of cooling capability. Two-dimensional, transient analytical models have been developed to explore this phenomenon with both continuous and staggered fin cores. Staggered fin predictions are compared to flight test data from the E-2C Allison T56 engine lube oil system during winter conditions. For simpler calculations, a viscosity ratio correction was introduced and found to provide reasonable cold ambient performance predictions for the staggered fin core, using a one-dimensional approach.
- Citation
- Coleman, K. and Kosson, R., "Analytical Methods to Predict Liquid Congealing in Ram Air Heat Exchangers During Cold Operation," Intersociety Conference on Environmental Systems, San Diego, California, United States, July 24, 1989, https://doi.org/10.4271/891439.