The Analysis and Testing of Gauge Fogging

941803

09/01/1994

Authors
Abstract
Content
The fogging of gauge lenses on various heavy duty vehicles has been a problem but the evaluation of various solutions has been an intuitive instead of a quantitative process. This paper details the causes, prevention and testing of the fogging of the lens on air-core gauges (indicating units) covered by SAE J1810. The following three areas are evaluated: internal and external sources of moisture and heat that can cause gauge lens fogging, gauge and vehicle design improvements and tests to rank alternate gauge designs for resistance to lens fogging.
Meta Tags
Topics
Details
DOI
https://doi.org/10.4271/941803
Pages
7
Citation
Copeland, L., and Nock, S., "The Analysis and Testing of Gauge Fogging," SAE Technical Paper 941803, 1994, https://doi.org/10.4271/941803.
Additional Details
Publisher
Published
Sep 1, 1994
Product Code
941803
Content Type
Technical Paper
Language
English