Analysis of Particle Concentrations and Smoke in Common-Rail Diesel Engine

2008-01-1743

06/23/2008

Event
2008 SAE International Powertrains, Fuels and Lubricants Congress
Authors Abstract
Content
The article shows the results of particulate matter emissions obtained in the ESC cycle. In order to carry out the tests different devices were applied for the measurement of particular matter (AVL Smart Sampler - measurement by means of a gravimetric method of a partial exhaust smoke dilution, Horiba Mexa 1220 PM - measurement with the use of two flame ionizing detectors), which were then compared to the smokiness values (AVL 415 - measurement of exhaust smoke values, Opacimetr 439 - measurement of exhaust opacity). Having compared the obtained correlation results, main relationships of fractional composition of particular matter, obtained in the tests, were defined.
Meta TagsDetails
DOI
https://doi.org/10.4271/2008-01-1743
Pages
9
Citation
Merkisz, J., and Pielecha, J., "Analysis of Particle Concentrations and Smoke in Common-Rail Diesel Engine," SAE Technical Paper 2008-01-1743, 2008, https://doi.org/10.4271/2008-01-1743.
Additional Details
Publisher
Published
Jun 23, 2008
Product Code
2008-01-1743
Content Type
Technical Paper
Language
English