Analysis of Leakage Causes of 6ADG011VR Branch Pipe in a Power Plant

2026-99-0231

7/31/2026

Authors
Abstract
Content
The socket-welded branch pipes of a power plant leaked and failed in the ADG System. To find the cause of the failure, this paper analyzed the failure reasons of the socket-welded branch pipes through macroscopic inspection, chemical composition analysis, mechanical performance test, metallographic inspection, and fracture microscopic analysis. The results show that the failure mode leading to leakage in socket-welded pipelines is fatigue cracking, which initiated at the weld toe on the outer wall and propagated inward. The vibration generated by the system environment is the main cause of fatigue cracking of socket-welded branch pipes.
Meta TagsDetails
DOI
https://doi.org/10.4271/2026-99-0231
Citation
Zhu, J., "Analysis of Leakage Causes of 6ADG011VR Branch Pipe in a Power Plant," The 10th International Conference on Mechanical Manufacturing Technology and Material Engineering (MMTME 2025), Shenyang, China, September 19, 2025, https://doi.org/10.4271/2026-99-0231.
Additional Details
Publisher
Published
17 hours ago
Product Code
2026-99-0231
Content Type
Technical Paper
Language
English