Allocating Radiant Interchange Factors with Corner Node Modeling

972538

07/01/1997

Event
International Conference On Environmental Systems
Authors Abstract
Content
Placing the thermal nodes at the corners of the radiation surfaces results in greater thermal-model accuracy for a given number of nodes, as compared to the more common practice of placing the thermal nodes at the center of the radiation surfaces. Placing the thermal nodes at the corners does, however, add complications in computing radiant interchange factors. In this paper the accuracy of subdividing elements into radiation sub-elements is compared to the accuracy of allocating elemental radiation couplings to the corner nodes. The comparison shows that, for a given number of nodes, the two methods have nearly the same accuracy, provided good modeling practice is followed in both cases.
Meta TagsDetails
DOI
https://doi.org/10.4271/972538
Pages
6
Citation
Costello, C., and Costello, F., "Allocating Radiant Interchange Factors with Corner Node Modeling," SAE Technical Paper 972538, 1997, https://doi.org/10.4271/972538.
Additional Details
Publisher
Published
Jul 1, 1997
Product Code
972538
Content Type
Technical Paper
Language
English