Accelerated Testing of Various Types of Vacuum Fluorescent Displays

890810

02/01/1989

Event
SAE International Congress and Exposition
Authors Abstract
Content
The VFD tests in this report differ from previous tests in that the anode and grid supply voltages, in addition to the filament supply voltage, were simultaneously increased from nominal values. Accelerated tests were conducted at 110%, 125%, and 150% of nominal voltage on VFD's having static and duplex drive with AC-driven filament and static drive with DC-driven Filament. Two methods are used to estimate the time at which 50% degradation occurs in luminance at nominal (100%) voltage. These methods were the inverse power law and regression analysis.
Meta Tags
Topics
Affiliated or Co-Author
Details
DOI
https://doi.org/10.4271/890810
Pages
8
Citation
Stephenson, H., "Accelerated Testing of Various Types of Vacuum Fluorescent Displays," SAE Technical Paper 890810, 1989, https://doi.org/10.4271/890810.
Additional Details
Publisher
Published
Feb 1, 1989
Product Code
890810
Content Type
Technical Paper
Language
English