A Numerical Simulation of Ignition Delay in Diesel Engines
980501
02/23/1998
- Event
- Content
- To investigate the ignition process in a diesel spray, the ignition in a transient fuel spray is analyzed numerically by a simple quasi-steady spray model coupled with the Shell kinetics model at various operating conditions and validity of this model is assessed by a comparison with existing experimental data. The calculated results indicate that the competition between the heat absorption of fuel and the hot air entrainment determines the equivalence ratio of mixtures favorable for the ignition to occur in the shortest time.
- Pages
- 9
- Citation
- Kamimoto, T., Akiyoshi, M., and Kosaka, H., "A Numerical Simulation of Ignition Delay in Diesel Engines," SAE Technical Paper 980501, 1998, https://doi.org/10.4271/980501.