In the present study, a louvered fin configuration widely used in automotive heat exchangers for engine and motor cooling applications is investigated. Extensive numerical and experimental studies available in the literature have focused on performance optimization by varying key geometric parameters, like as fin depth, fin length, fin pitch, louver pitch, louver length, and louver angle. A systematic steady-state numerical analysis is performed on aluminum louvered fins having different louver angles of 15°, 19°, 23°, and 27°. The influence of louver-to-fin pitch ratios (Lp/Fp) of 0.25, 0.6, and 0.79 are examined over a Reynolds number range of 207 to 622 to evaluate thermo-hydraulic performance. The tube wall temperature is considered at 90 °C, while the inlet air temperature is set to 30 °C. The performance of the louvered fin is assessed based on key air-side parameters, including convective heat transfer coefficient, pressure drop, Colburn j factor and Fanning friction factor (f) along with an overall thermal performance factor. The results are compared for different combinations of louver angle, louver-to-fin pitch ratio across the specified Reynolds number range. The study identifies the optimal geometric configuration that provides enhanced thermo-hydraulic performance by achieving an effective adjustment between heat transfer augmentation as well as pressure drop penalty.