A New Method to Automatically Optimize the Knock Detection Level in the Knock Control System

891964

9/1/1989

Authors
Abstract
Content
A new method of determining the knock detection level, which is very important for KCS, has been developed on the basis of the following statistics. The logarithmic transformed value of the knock sensor signal peak level showed its normal distribution on non-knock conditions, which distribution was, however, diverted to its larger side under knock conditions. The difference of distributions was clarified on the probability paper. The former formed a straight line, while the latter did an broken line with a break point, indicating a frequency of knock occurrence. This break point was employed to obtain the KCS with its optimal knock detection level.
Meta Tags
Topics
Affiliated or Co-Author
Details
DOI
https://doi.org/10.4271/891964
Pages
12
Citation
Iwata, T., Sakakibara, K., and Haragucti, H., "A New Method to Automatically Optimize the Knock Detection Level in the Knock Control System," SAE Technical Paper 891964, 1989, https://doi.org/10.4271/891964.
Additional Details
Publisher
Published
9/1/1989
Product Code
891964
Content Type
Technical Paper
Language
English