A Computer Analysis of Regenerator Losses in a Stirling Cryocooler with Multiple Expansion Stages

929038

08/03/1992

Event
27th Intersociety Energy Conversion Engineering Conference (1992)
Authors Abstract
Content
An Ideal Adiabatic analysis of a Stirling cryocooler with multiple expansion stages has been presented previously. In this analysis the compression space and the various expansion spaces are adiabatic, the heat exchangers are isothermal and the regenerators are ideal. This paper is an extension of that analysis to evaluate the enthalpy losses associated with the interstage regenerators. The regenerator effectiveness is defined in terms of the total unidirectional heat flow from the regenerator matrix to the working gas. A new definition of regenerator figure-of-merit is proposed for the intermediate expansion stages based on a stage energy balance, and its evaluation and uses in design are discussed. The analysis of a typical three expansion stage cryocooler is presented.
Meta TagsDetails
DOI
https://doi.org/10.4271/929038
Pages
5
Citation
Urieli, I., and Kuo-Chiang, T., "A Computer Analysis of Regenerator Losses in a Stirling Cryocooler with Multiple Expansion Stages," SAE Technical Paper 929038, 1992, https://doi.org/10.4271/929038.
Additional Details
Publisher
Published
Aug 3, 1992
Product Code
929038
Content Type
Technical Paper
Language
English