A Capillary Pump Loop Cooling System for the NICMOS Instrument

981814

07/13/1998

Event
International Conference On Environmental Systems
Authors Abstract
Content
The Near Infrared Camera and Multi Object Spectrometer (NICMOS) was installed in the Hubble Space Telescope in February 1997. Shortly thereafter, the instrument experienced a thermal short in its solid nitrogen dewar system which will shorten its useful life significantly. A reverse Brayton cycle mechanical refrigerator will be installed during the third servicing mission (SM3) to provide cooling for the instrument, and thereby extend its life. A Capillary Pump Loop (CPL) and radiator system has been designed, built and tested to remove up to 500 watts of heat from the mechanical cooler and its electronics. This paper will describe the CPL system in detail and present the results of the extensive testing and qualification program.
Meta TagsDetails
DOI
https://doi.org/10.4271/981814
Pages
8
Citation
McIntosh, R., Kaylor, M., Buchko, M., Kroliczek, E. et al., "A Capillary Pump Loop Cooling System for the NICMOS Instrument," SAE Technical Paper 981814, 1998, https://doi.org/10.4271/981814.
Additional Details
Publisher
Published
Jul 13, 1998
Product Code
981814
Content Type
Technical Paper
Language
English