On the Vibrational Power Flow from Engine to Elastic Structure through Single and Double Resilient Mounting Systems
Annotation ability available
Sector:
Language:
English
Abstract
The vibrational power flows in double and single resilient mounting systems is investigated. The formulas are based upon modal parameters of each structure in mounting system. An simple example is given for illustration.
Authors
Citation
Qu, J. and Qian, B., "On the Vibrational Power Flow from Engine to Elastic Structure through Single and Double Resilient Mounting Systems," SAE Technical Paper 911057, 1991, https://doi.org/10.4271/911057.Also In
References
- Goyder H.G.D. White R.C. “Vibrational power flow from machines into built-up structure” J. of Sound and Vibration 60 1 1980
- Snowden J.C. “Vibration isolation: use and characterization” J. Acoust. Soc. Am. 66 5 1979
- Unger E.E. “High-frequency vibration isolation” J. of Sound and Vibration 4 1966
- Peterson B. Plunt J. “On effective mobilities in the prediction of structure-borne sound transmission between a source structure and a receiving structure” J. of Sound and Vibration 82 4 1982
- Pinnington R.J. “vibrational power transmission between sources and substructures” University of Southampton England 1983
- Harris C. Grede C.E. “Shock and Vibration Handbook” 2nd 1976