Thin-Film Magnetic-Field-Response Fluid-Level Sensor for Non-Viscous Fluids
TBMG-2701
04/01/2008
- Content
An innovative method has been developed for acquiring fluid-level measurements. This method eliminates the need for the fluid-level sensor to have a physical connection to a power source or to data acquisition equipment. The complete system consists of a lightweight, thin-film magnetic-field-response fluid-level sensor (see Figure 1) and a magnetic field response recorder that was described in “Magnetic-Field-Response Measurement-Acquisition System” (LAR-16908-1), NASA Tech Briefs, Vol. 30, No. 6 (June 2006), page 28.
- Citation
- "Thin-Film Magnetic-Field-Response Fluid-Level Sensor for Non-Viscous Fluids," Mobility Engineering, April 1, 2008.