Integral Battery Power Limiting Circuit for Intrinsically Safe Applications
TBMG-8153
07/01/2010
- Content
A circuit topology has been designed to guarantee the output of intrinsically safe power for the operation of electrical devices in a hazardous environment. This design uses a MOSFET (metal–oxide– semiconductor field-effect transistor) as a switch to connect and disconnect power to a load. A test current is provided through a separate path to the load for monitoring by a comparator against a preset threshold level. The circuit is configured so that the test current will detect a fault in the load and open the switch before the main current can respond. The main current passes through the switch and then an inductor. When a fault occurs in the load, the current through the inductor cannot change immediately, but the voltage drops immediately to safe levels.
- Citation
- "Integral Battery Power Limiting Circuit for Intrinsically Safe Applications," Mobility Engineering, July 1, 2010.