Hybrid Transformer

TBMG-34733

7/1/2019

Abstract
Content

Researchers have developed a hybrid transformer that has the benefit of a full planar transformer design but uses a wire-wound secondary winding to keep the parasitic winding capacitances lower. Alone, planar transformers have the advantage of a lower profile and better reproducibility, but wire-wound transformers allow for less parasitic capacitances. By combining elements from traditional wire-wound transformers and planar transformers, the overall performance and reliability were improved.

Meta TagsDetails
Citation
"Hybrid Transformer," Mobility Engineering, July 1, 2019.
Additional Details
Publisher
Published
7/1/2019
Product Code
TBMG-34733
Content Type
Magazine Article
Language
English