Magazine Article

Finding a Solution for Bellows Coupling Failure

TBMG-29799

8/1/1999

Abstract
Content

When a problem such as breaking bellows couplings threatens to halt a machinery production line, it is necessary to look beyond the obvious. In an application in which the coupling works on a Heidenhain encoder for an X-Y table that positions circuit boards, representatives of the user company and of Servometer determined that it was a flexing type failure rather than a torquing failure. There were two couplings per handling machine, and calculation showed that the peak torque transmitted through the coupling was 0.22 in.-oz. After a thorough analysis, it was clear that the existing bellows coupling was failing because of offset, since the failure was in the first convolution closest to the end piece.

Meta TagsDetails
Citation
"Finding a Solution for Bellows Coupling Failure," Mobility Engineering, August 1, 1999.
Additional Details
Publisher
Published
8/1/1999
Product Code
TBMG-29799
Content Type
Magazine Article
Language
English