Magazine Article

Dual Cryogenic Capacitive Density Sensor

TBMG-5395

07/01/2009

Abstract
Content

A dual cryogenic capacitive density sensor has been developed. The device contains capacitive sensors that monitor two-phase cryogenic flow density to within ±1% accuracy, which, if temperature were known, could be used to determine the ratio of liquid to gas in the line. Two of these density sensors, located a known distance apart, comprise the sensor, providing some information on the velocity of the flow.

Meta TagsDetails
Citation
"Dual Cryogenic Capacitive Density Sensor," Mobility Engineering, July 1, 2009.