Composite Pulse Tube

TBMG-2190

9/1/2007

Abstract
Content

A modification of the design of the pulse tube in a pulse-tube cryocooler reduces axial thermal conductance while preserving radial thermal conductance. It is desirable to minimize axial thermal conductance in the pulse-tube wall to minimize leakage of heat between the warm and cold ends of the pulse tube. At the same time, it is desirable to maximize radial thermal conductance at the cold end of the pulse tube to ensure adequate thermal contact between (1) a heat exchanger in the form of a stack of copper screens inside the pulse tube at the cold end and (2) the remainder of the cold tip, which is the object to which the heat load is applied and from which heat must be removed. The modified design yields a low-heat-leak pulse tube that can be easily integrated with a cold tip.

Meta TagsDetails
Citation
"Composite Pulse Tube," Mobility Engineering, September 1, 2007.
Additional Details
Publisher
Published
9/1/2007
Product Code
TBMG-2190
Content Type
Magazine Article
Language
English