Hybrid Iii Family Chest Potentiometer Calibration Procedure
- Ground Vehicle Standard
- J2517_200006
- Issued
Sector:
Issuing Committee:
Language:
English
Scope
This procedure establishes a recommended practice for establishing the sensitivity of the chest displacement potentiometer assembly used in the Hybrid III family of Anthropomorphic Test Devices (ATDs, or crash dummies). This potentiometer assembly is used in the Hybrid III family to measure the linear displacement of the sternum relative to the spine (referred to as chest compression). An inherent non-linearity exists in this measurement because a rotary potentiometer is being used to measure a generally linear displacement. As the chest cavity is compressed the potentiometer rotates, however the relationship between the compression and the potentiometer rotation (and voltage output) is non-linear.
Crash testing facilities have in the past used a variety of techniques to calibrate the chest potentiometer, that is to establish a sensitivity value (mm/(volt/volt) or mm/(mvolt/volt)). These sensitivity values are used to convert recorded voltage measurements to engineering units, in this case chest compression in mm. Some of these techniques intended to correct for the non-linearity and others did not. Of those that did correct for the non-linearity, there was a variation in techniques used. This variation in calibration procedures was in part identified by the SAE Dummy Testing Equipment Subcommittee (DTES), and led to overall variability in chest compression measurements between laboratories.
The intent of this SAE Recommended Practice is to minimize the variations in chest deflection measurements between crash testing laboratories. Before this procedure was written, a round robin showed variations for the Small Female of 10% among 8 labs for the chest pot sensitivity value. A follow-up round robin to test this procedure showed a worst case variation of 2.7% among 10 labs, with a standard deviation of 0.9%. The calibration procedure recommended here uses a two-point calibration and is not intended to correct for the non-linearity (which, for example, is as large as 3% for the Small Female but is small near the peak). It also does not require the measurement of a starting position of the potentiometer before each crash test, thus it does not correct for the difference in starting chest geometry between a subject dummy and its design intent. It is intended to be a simple and reproducible calibration procedure which crash test facilities can easily adopt with little or no modifications to their facilities. More complex procedures could in fact address the non-linearity, but at the likely cost of non-adoption by some facilities.
Data Sets - Support Documents
No Datasets Available
Issuing Committee
Dummy Testing and Equipment Committee
The Dummy Testing Equipment Committee (DTEC) is a group of experts with experience in the area of certification and handling of Anthropomorphic Test Devices (ATD), more commonly known as crash test dummies, and equipment related to ATD. The DTEC seeks to standardize the use and certification of ATD so that test data are both repeatable and reproducible.
Reference
Number | Title |
---|---|
EngineeringAid25 | This document is not part of the subscrption. |
EngineeringAid26 | This document is not part of the subscrption. |
FMVSS No.572 | This document is not part of the subscrption. |
FMVSSPart572 | This document is not part of the subscrption. |
J211/1_201403 | Instrumentation for Impact Test - Part 1 - Electronic Instrumentation |
J2570_201911 | Performance Specifications for Anthropomorphic Test Device Transducers |
J2706_201306 | Hybrid III Six-Year-Old Child Dummy User's Manual |
J2857_202301 | This document is not part of the subscrption. |
* Redlines comparisons are available for those standards
listed in the Revision History that contain a radio button. A
redline comparison of the current version against a revision is
accomplished by selecting the radio button next to the standard and
then selecting 'compare'. At this time, Redline versions only exist
for some AMS standards. SAE will continue to add redline versioning
with ongoing updates to SAE MOBILUS.