AIR4275A Jet Reference Fluid Study for Fuel Tank Sealants

Stabilized

01/17/2012

Features
Issuing Committee
Scope
Content
Standard reference fluids, or test fluids, have long been used to evaluate the effects of hydrocarbon fuels on various materials, such as integral fuel tank sealants. Standard fluids are required because hydrocarbon fuels, such as JP-4, vary widely in composition depending on crude source, refining techniques, and other factors. To ensure reliable and reproducible results when determining the fuel resistance of materials, reference fluids of known composition, using worst case fuel compositions, are used. The current Jet Reference Fluid (JRF) called out in military sealant specifications was developed in the mid-1950s specifically as a JP-4 type test fluid formulation to be used for the accelerated laboratory testing of integral fuel tank sealants.
In August 1978, chalking of the polysulfide sealant in integral fuel tanks of some new aircraft at Edwards Air Force Base in California was discovered after only 1 year of service. Although chalking of polysulfide sealants had been observed occasionally in the past, the rate of chalking was unprecedented. The results of an investigation showed that the rapid chalking of the polysulfide sealant was caused by a chemical reaction involving metal ions (copper, cadmium, lead, and iron) and mercaptan sulfur in the fuel. It was also noted that qualification testing of the sealant used had not predicted the chalking that occurred in service. Further investigation disclosed that the sealant had passed the chalking test in the military specification because the JRF used in the specifications chalking test did not contain trace metal ions as did the fuel removed from the tanks of the affected aircraft. The special Air Force investigating team included in its final report a recommendation that the JRF specification be reviewed and revised.
The above chalking incident coupled with concerns resulting from deficiencies observed with the current JRF, and from changing sources of JP-4 indicated that an update of the JRF formulation in the sealant specifications was needed. A proposal was made to the SAE Aerospace Sealing Committee (G-9) which then formed a subcommittee for the development of a new Jet Reference Fluid (JRF) for evaluation of integral fuel tank sealants with Mr. W. F. Anspach as its chairman. The subcommittee members were:
Rationale
Content
This document has been determined to contain basic and stable technology which is not dynamic in nature.
Meta TagsDetails
DOI
https://doi.org/10.4271/AIR4275A
Pages
98
Citation
SAE International Information Report, Jet Reference Fluid Study for Fuel Tank Sealants, SAE Standard AIR4275A, Stabilized January 2012, Issued April 1991, https://doi.org/10.4271/AIR4275A.