Testing and Operation of the Purification Unit of the System for Water Recovery from Humidity Condensate (WRS-C) with a Higher Content of Organic Contaminants
981715
07/13/1998
- Event
- Content
- The paper presents the results of ground and flight (on OSS Mir) tests of an updated purification assembly of the WRS-C system outfitted with a filter-reactor. The tests have proved that the filter-reactor oxidizes effectively basic organic contaminants in humidity condensate including ethyleneglycol to ones that easily undergo sorption, enables the operation of the recovery system in the event of an off-design increase in organic contaminants in condensate and significantly improves the lifetime of the purification assembly. The data obtained confirm a wise selection of the purification assembly hardware for the system for water recovery from humidity condensate WRS-CM for the ISS service module.
- Pages
- 8
- Citation
- Samsonov, N., Bobe, L., Novikov, V., Farafonov, N. et al., "Testing and Operation of the Purification Unit of the System for Water Recovery from Humidity Condensate (WRS-C) with a Higher Content of Organic Contaminants," SAE Technical Paper 981715, 1998, https://doi.org/10.4271/981715.