Radiation Dose Prediction for Space Station

860924

07/14/1986

Authors
Abstract
Content
Significant differences in dose prediction for Space Station arise depending on whether or not the magnetic field model is extrapolated into the future. The basis for these calculations is examined in detail, and the importance of the residual atmospheric layer at altitudes below 1,000 km, with respect to radiation attenuation is emphasized.
Dosimetry results from shuttle flights are presented and compared with the computed results. It is recommended that, at this stage, no extrapolation of the magnetic field into the future be included in the calculations. A model adjustment, to replace this arbitrary procedure is presented. Dose predictions indicate that, at altitudes below 500 km and low inclination, and with nominal module wall thicknesses (.125 inch aluminum), orbit stay time of 90 days in Space Station are well within present radiation limit guidelines.
Meta TagsDetails
DOI
https://doi.org/10.4271/860924
Pages
18
Citation
McCormack, P., "Radiation Dose Prediction for Space Station," SAE Technical Paper 860924, 1986, https://doi.org/10.4271/860924.
Additional Details
Publisher
Published
Jul 14, 1986
Product Code
860924
Content Type
Technical Paper
Language
English