Lightning Current Transfer Characteristics of the P-Static Discharger Installations

700923

2/1/1970

Authors
Abstract
Content
This paper presents the results of p-static discharger installation lightning tests conducted by the Douglas Aircraft Co. at its Long Beach, California, facilities and the facilities of the Lightning and Transients Research Institute at Miami Beach, Florida. The paper discusses the lightning current transfer characteristics and lightning protection design considerations for the p-static discharger, the discharger retainer, and the aircraft installation. Laboratory lightning test results are also discussed in relationship with the in-service experience associated with natural lightning stroke incidents.
Meta TagsDetails
DOI
https://doi.org/10.4271/700923
Citation
Amason, M. and Kung, J., "Lightning Current Transfer Characteristics of the P-Static Discharger Installations," SAE/USAF Lighting and Static Electricity Conference, San Diego, California, United States, December 9, 1970, https://doi.org/10.4271/700923.
Additional Details
Publisher
Published
2/1/1970
Product Code
700923
Content Type
Technical Paper
Language
English