Frequency Response of a Proportional Fluid Amplifier

670903

02/01/1967

Event
National Fuels and Lubricants, Powerplants, Transportation Meetings
Authors Abstract
Content
This paper demonstrates that linear lumped parameter models of proportional fluid amplifiers are valid until the resonant frequency of the output receiver is approached. The reported experimental results are for variations in the output load resistance only. Variations in power jet pressure and output impedance may change the frequency where the amplifier departs from the predicted response.
The experimental procedure and frequency response test results are discussed.
Meta TagsDetails
DOI
https://doi.org/10.4271/670903
Pages
9
Citation
Strunk, R., and Bowman, D., "Frequency Response of a Proportional Fluid Amplifier," SAE Technical Paper 670903, 1967, https://doi.org/10.4271/670903.
Additional Details
Publisher
Published
Feb 1, 1967
Product Code
670903
Content Type
Technical Paper
Language
English