This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Method of Improvement of Air Flow Uniformity to Reduce the Evaporator Frosting of a Passenger Car
Technical Paper
2021-28-0148
ISSN: 0148-7191, e-ISSN: 2688-3627
This content contains downloadable datasets
Annotation ability available
Sector:
Language:
English
Abstract
For an efficient automotive AC system it is very essential to ensure uninterrupted and consistent airflow and temperature at the vent exit to help achieve the comfortable cabin space. This certainly requires temperature sensor to position at lowest possible temperature on heat exchanger and uniform flow distribution over it. However the uneven distribution of airflow on evaporator entry face leads to lowest temperature and sometimes goes undetected. This causes the condensate to get freezed and then frosting occurs at the core surface. Eventually a substantial portion of evaporator face gets choked and gradually airflow reduces and evaporator exit air temperature shoots up. Hence it is very important to prevent the frosting on evaporator core so to have uninterrupted airflow and adequate cooling in the passenger compartment.
The present paper investigates the reasons for frosting occurring in one of the hatchback vehicle in bench test. The investigation consists of conducting anti-freezing tests under some test conditions. Further numerical simulation was performed to understand the flow pattern over the evaporator. Flow simulation was carried out in STAR CCM+ software. The numerical results of evaporator flow distribution exhibit almost the same area where the frosting was occurring. In order to improve the flow uniformity ratio over the evaporator further design iterations were done and flow analysis was executed. Once the desired level of uniformity ratio is achieved, prototypes were made and tested in bench under same conditions. The numerical simulation results were in good agreement with that of experimental results and eventually the frosting was avoided. Hence involving numerical simulation at early stages of design cycle really helps in robust design.
Recommended Content
Technical Paper | Automotive Windshield Ice-Clearing Analysis |
Technical Paper | Validation of Computational Vehicle Windshield De-Icing Process |
Technical Paper | Computer-Based Modeling and Simulation for Vehicle Rail Shipping Impact Analysis |
Authors
Topic
Citation
SEN, A., SEN, S., Parayil, P., and Goel, A., "Method of Improvement of Air Flow Uniformity to Reduce the Evaporator Frosting of a Passenger Car," SAE Technical Paper 2021-28-0148, 2021, https://doi.org/10.4271/2021-28-0148.Data Sets - Support Documents
Title | Description | Download |
---|---|---|
Unnamed Dataset 1 | ||
Unnamed Dataset 2 | ||
Unnamed Dataset 3 | ||
Unnamed Dataset 4 |
Also In
References
- Ye , H.Y. , Park , J.S. , and Lee , K.S. Frost Retardation on Fin-Tube Heat Exchangers Using Mass Transfer Characteristics with Respect To Air Velocity Int J Heat Mass Transfer 79 2014 689 693
- Chen , H. , Thomasb , L. , and Besanta , R.W. Fan Supplied Heat Exchanger Fin Performance Under Frosting Conditions Int J Refrig 26 2013 140 149
- Aljuwayhel , N.F. , Reindl , D.T. , Klein , S.A. , and Nellis , G.F. Experimental Investigation of the Performance of Industrial Evaporator Coils Operating Under Frosting Conditions International Journal of Refrigeration 31 2008 98 106
- Huang , J.M. , Hsieh , W.C. , Ke , X.J. , and Wang , C.C. The Effects of Frost Thickness on the Heat Transfer of Finned Tube Heat Exchanger Subject to the Combined Influence of Fan Types Appl Therm Eng 28 2008 728 737
- Groll , E.A. , Braun , J.E. , and Bach , C.K. Optimizing Refrigerant Distribution in Evaporators. Final Project Report Prepared for California Energy Commission USA Purdue University 2011
- Padhmanabhan , S.K. , Fisher , D.E. , Cremaschi , L. , and Moallem , E. Modeling Non-uniform Frost Growth on a Finand-Tube Heat Exchanger International Journal of Refrigeration 34 2011 2018 2030
- Haijie , Q. , Weizhong , L. , Bo , D. , Zhihai , Z. et al. Experimental Study of the Characteristic of Frosting on Low-Temperature Air Cooler International Journal of Experimental Thermal and Fluid Science 55 2014 106 114
- Londero , D.S.D. 2012 Frost Formation on Fan-Supplied Tube-Fin Evaporators: A Visual and Numerical Analysis International Refrigeration and Air Conditioning Conference. Paper 1164 Purdue University USA
- Tashiro , Y. , Hamada , M. 2014 Experimental Evaluation of the Frost Formation International refrigeration and air conditioning conference. Paper 1395 Purdue University USA
- Koern , M.L. , Brix , W. , Elmegaard , B. , and Larsen , L. Performance of Residential Air-Conditioning Systems with Flow Maldistribution in Fin-and-Tube Evaporators International Journal of Refrigeration 34 2011 696 706
- Sommers , A.D. and Jacobi , A.M. Air-Side Heat Transfer Enhancement of a Refrigerator Evaporator Using Vortex Generation International Journal of Refrigeration 28 2005 2005 1006 1017
- Bayrak , E. Experimental Investigation of Frost Formation in a Finned-Tube Evaporator under Simulated Real Operation Conditions International Refrigeration and Airconditioning 2016
- Mallikarjuna , P. Performance Analysis Of Domestic Refrigerator By Using 662 SSilicone Grease Coating On The Evaporator International Journal of Engineering and Techniques 1 1 2015