Use of Partial Recirculation to Limit Build-Up of Cabin Carbon Dioxide Concentrations to Safe Limits per ASHRAE Standard-62
Technical Paper
2020-01-1245
ISSN: 0148-7191, e-ISSN: 2688-3627
This content contains downloadable datasets
Annotation ability available
Sector:
Language:
English
Abstract
Carbon dioxide exhaled by occupants remains within the cabin during operation of HVAC unit in recirculation mode. The CO2 inhaled by the occupants goes into their blood stream that negatively affects occupant’s health. ASHRAE Standard-62 (1999) specifies the safe levels of carbon dioxide in conditioned space for humans. The CO2 concentration limit per ASHRAE is 700 ppm over ambient conditions on a continuous basis. Based on the test data, at worst case scenario (idle condition where body leakage will be a minimal) results in CO2 concentrations of 1601, 2846, 4845 and 6587 ppm respective for 1 to 4 occupants in 30 minutes.
Author has also conducted test by imposing ASHRAE standard-62. A controller was programmed for operating the blower unit’s intake door to go from recirculation to OSA mode when the measured carbon dioxide ppm level goes above 1100 ppm. The door stays in OSA mode until the cabin carbon dioxide falls to approximately 500ppm. By imposing these limits, the blower unit’s intake door cycles between 3 minutes to 6.5 minutes with four to one occupants in the cabin. Hence, cycle time for two and three occupants in cabin will fall between 3 to 6.5 minutes.
ASHRAE Standard-62 has an additional requirement for maintaining good air quality within the ambient condition. Per this requirement, we need to introduce a min of 15 cfm/person (0.43 m3/min) in the conditioned space to maintain good air quality. Even though this requirement is primarily for elimination the body odors, the author has investigated if this airflow requirement is also sufficient to maintain cabin CO2 concentrations as stated above. For the vehicle investigated, the above data represents a partial recirculation factor (PRF) of 19.2%. Based on the simulation and experimentation, it was determined that this PRF is not sufficient to maintain cabin carbon dioxide concentrations below 1100ppm. A PRF of approximately 40% was required to maintain the cabin carbon dioxide concentrations per ASHRAE standard (i.e., ppm level <=1100ppm).
Finally, partial pressures of CO2 and O2 have also been presented along with O2 concentrations within the cabin. Based on the idle condition, partial pressure for CO2 increased by 660 Pa in 30 minutes of test drive with 4 occupants. Detailed results have been presented in the paper.
Recommended Content
Technical Paper | Investigation of the Effects of Wheel Slip on Vehicle Emissions and Fuel Economy |
Technical Paper | Coordinated Control of Multi-Degree-of Freedom Fuel Systems |
Journal Article | Drivetrain Energy Distribution and Losses from Fuel to Wheel |
Citation
Mathur, G., "Use of Partial Recirculation to Limit Build-Up of Cabin Carbon Dioxide Concentrations to Safe Limits per ASHRAE Standard-62," SAE Technical Paper 2020-01-1245, 2020, https://doi.org/10.4271/2020-01-1245.Data Sets - Support Documents
Title | Description | Download |
---|---|---|
Unnamed Dataset 1 | ||
Unnamed Dataset 2 | ||
Unnamed Dataset 3 | ||
Unnamed Dataset 4 | ||
Unnamed Dataset 5 |
Also In
References
- American Association of Clinical Chemistry 2019 www.aacc.org
- Amin , J. , Dienhart , B. , and Wertenbach , J. Safety Aspects of an AC System with Carbon Dioxide as Refrigerant SAE Alternative Refrigerant Conference Scottsdale, AZ 2004
- ASHRAE/ANSI, Standard 62-1999 1999
- ASHRAE Handbook 2019
- Bosh Sensor 2 Aug 2006 www.semiconductors.bosch.de
- Boulawz , E. and Clodic , D. Safety Assessment: Characterization of CO 2 Concentration in Car Cabin during MAC Loop Leakage and Passenger Breathing MAC Workshop Torino 2007
- CARB 2007
- EPA 2010
- GSCE 2019 https://www.bbc.co.uk/bitesize/guides/z6h4jxs/revision/3
- Grady , M.L. et al. Vehicle Cabin Air Quality with Fractional Air Recirculation SAE Technical Paper 2013-01-1494 2013 https://doi.org/10.4271/2013-01-1494
- Hudda , N. and Fruin , S.A. Carbon Dioxide Accumulation inside Vehicle: The Effect of Ventilation and Driving Conditions Science of the Total Environment 610-611 1448 1456 2018
- Jung , H.S. et al. Simultaneously Reducing CO2 and Particulate Exposures via Fractional Recirculation of Vehicle Cabin Air Atmos Environ 160 77 88 2017
- Luangprasert , M. 2017 In-Vehicle Carbon Dioxide Concentration in Commuting Cars in Bangkok, Thailand Journal of Air & Waste Management 17 5 623 633
- Mathur , G.D. Experimental Investigation to Monitor Vehicle Cabin Indoor Air Quality (IAQ) in the Detroit Metropolitan Area SAE Technical Paper 2006-01-0269 2006 2006 https://doi.org/10.4271/2006-01-0269
- Mathur , G.D. Experimental Investigation to Monitor Tailpipe Emissions Entering into Vehicle Cabin to Improve Indoor Air Quality (IAQ) SAE Technical Paper 2007-01-0539 2007a https://doi.org/10.4271/2007-01-0539
- Mathur , G.D. 2007b
- Mathur , G.D. Field Tests to Monitor Build-Up of Carbon Dioxide in Vehicle Cabin with AC System Operating in Recirculation Mode for IAQ and Safety SAE Int. J. Passeng. Cars - Mech. Syst. 1 1 757 767 2008 2009 https://doi.org/10.4271/2008-01-0829
- Mathur , G.D. Field Monitoring of Carbon Dioxide in Vehicle Cabin to Monitor Indoor Air Quality and Safety in Foot and Defrost Modes SAE Technical Paper 2009-01-3080 2009 https://e.org/10.4271/2009-01-3080
- Mathur , G.D. Experimental Investigation to Determine Influence of Build-Up of Cabin Carbon Dioxide Concentrations for Occupants Fatigue SAE Technical Paper 2016-01-0254 2016 https://doi.org/10.4271/2016-01-0254
- Mathur , G.D. Development of a Model to Predict Build-Up of Cabin Carbon Dioxide Concentrations in Automobiles for Indoor Air Quality SAE Technical Paper 2017-01-0163 2017 https://doi.org/10.4271/2017-01-0163
- Mathur , G.D. Effect of Cabin Volume on Build-Up of Carbon Dioxide Concentrations from Occupants Breathing in Automobiles SAE Technical Paper 2018-01-0074 2018a https://doi.org/10.4271/2018-01-0074
- Mathur , G.D. 2018b
- Mathur , G.D. Influence of Partial Recirculation on the Build-Up of Cabin Carbon Dioxide Concentrations SAE Technical Paper 2019-01-0908 2019 https://doi.org/10.4271/2019-01-0908
- MN State 2019 http://web.mnstate.edu/marasing
- NOAA 2019 http://www.esrl.noaa.gov/gmd/ccgg/trends/
- Persily , A. and Jonge , L. Carbon Dioxide Generation Rates for Building Occupants Indoor Air 27 5 868 879 2017
- RACE 1997
- Scott , J.L. et al. Occupational Hazards of Carbon di-Oxide Exposure Journal of Chemical Health & Safety, V 16 2 18 22 2009
- SAE Proposed Standard J2772 2007
- Tsutsumi , H. , Hoda , Y. , Tanabe , S. , and Arishiro , A. Effect of Car Cabin Environment on Driver’s Comfort and Fatigue SAE Technical Paper 2007-01-0444 2007 2007 https://doi.org/10.4271/2007-01-0444
- US Department of Transportation 2019 https://www.transportation.gov/
- UNEP (United Nation’s Environment Program) www.unep.org 2008
- Wark , K. Thermodynamics John Wiley 1971
- Atkinson , W. , Hill , W. , and Mathur , G.D. The Impact of Increased Air Recirculation on Interior Cabin Air Quality SAE Technical Paper 2017-01-0169 2017 https://doi.org/10.4271/2017-01-0169