Further Experimental Study of Asymmetric Plugging Layout on DPFs: Effect of Wall Thickness on Pressure Drop and Soot Oxidation
Technical Paper
2015-01-1016
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
In order to guide the development of asymmetric plugging layout Diesel Particulate Filters, hereafter referred to as “VPL-DPF”, in this paper we present some evaluation results regarding the effect of design parameters on the VPL-DPF performance. VPL-DPF samples which have different wall thicknesses (thin and thick walls) were evaluated in regards to their pressure drop and soot oxidation behaviors, with the aim to optimize the design of DPF structure. As a result of pressure drop evolution during soot loading, contrary to our expectation, in some cases, it was found out that VPL increases the transient pressure drop compared to the conventional plugging layout DPF. That meant there is an appropriate specific optimum wall thickness for adoption of VPL which has to be well defined at its structural design phase. Based on our previous research, it is expected that this result is due to interactions among the different (five) wall flows that exist in a VPL-DPF. Consequently, soot oxidation tests were conducted under certain flow gas conditions with a gas analyzer and it was confirmed that the VPL design slightly reduces the instantaneous soot oxidation rate for high values of soot conversion. That meant the VPL-DPF regenerates in a gentler fashion than the DPF with conventional plugging layout. It was, therefore, found that the adoption of VPL-DPF would increase the soot accumulation capacity of a DPF. Throughout these aforementioned tests, we were able to conclude that the developed VPL-DPF might have advantages from both pressure drop reduction and regeneration activity enhancement point of view.
Recommended Content
Authors
Citation
Iwata, H., Konstandopoulos, A., Nakamura, K., Ogiso, A. et al., "Further Experimental Study of Asymmetric Plugging Layout on DPFs: Effect of Wall Thickness on Pressure Drop and Soot Oxidation," SAE Technical Paper 2015-01-1016, 2015, https://doi.org/10.4271/2015-01-1016.Also In
References
- Konstandopoulos , A. and Johnson , J. Wall-Flow Diesel Particulate Filters-Their Pressure Drop and Collection Efficiency SAE Technical Paper 890405 1989 10.4271/890405
- http://www.dieselnet.com/tech/dpf_wall-flow.php
- Ohno , K. , Shimato , K. , Taoka , N. , Santae , H. et al. Characterization of SiC-DPF for Passenger Car SAE Technical Paper 2000-01-0185 2000 10.4271/2000-01-0185
- Taoka , N. , Ohno , K. , Hong , S. , Sato , H. et al. Effect of SiC-DPF with High Cell Density for Pressure Loss and Regeneration SAE Technical Paper 2001-01-0191 2001 10.4271/2001-01-0191
- Nakamura , K. , Konstandopoulos , A. , Kostoglou , M. , Shibata , T. et al. New Asymmetric Plugging Layout of Diesel Particulate Filters for the Pressure Drop Reduction SAE Technical Paper 2014-01-1512 2014 10.4271/2014-01-1512
- Konstandopoulos , A. and Kostoglou , M. Analysis of Asymmetric and Variable Cell Geometry Wall-Flow Particulate Filters SAE Int. J. Fuels Lubr. 7 2 489 495 2014 10.4271/2014-01-1510
- Konstandopoulos , A. , Zarvalis , D. , Kladopoulou , E. , and Dolios , I. A Multi-Reactor Assembly for Screening of Diesel Particulate Filters SAE Technical Paper 2006-01-0874 2006 10.4271/2006-01-0874
- Konstandopoulos , A. , Lorentzou , S. , Pagkoura , C. , Ohno , K. et al. Sustained Soot Oxidation in Catalytically Coated Filters SAE Technical Paper 2007-01-1950 2007 10.4271/2007-01-1950