Abstract
This paper reports on the first phase of a project that explores the trends and dependencies of the input power to the major mechanically-driven accessories including hydraulic pumps, air compressor, air conditioning (AC) compressor, and alternator on a modern parallel hybrid city bus. In this first phase, the impact of accessory electrification is estimated by considering the near-elimination of accessory overdrive and parasitic loading. In addition to reducing accessory fuel consumption accessory electrification can also serve as a bridge to the eventual use of a diesel or fuel cell auxiliary power unit to generate electricity for accessories on transit buses. Data collection and processing methods of this study are described, the shortcomings of mechanically-driven accessories are discussed, and an estimation of savings for accessory electrification is performed.
Over 11 days and 145.6 hours of data collection on routes through Minneapolis, the average input power to the accessories was 11.0 kW (AC off) and 19.3 kW (AC on). By approximating the impact of accessory overdrive and parasitic loading, it was calculated that replacing mechanically-driven accessories with their electrically-driven counterparts would reduce the accessory power demand by about 34% (AC off) and 31% (AC on). Under the conservative assumption that, with the air conditioning on, 50% of the bus's fuel is consumed by its accessories, it is estimated that accessory electrification would result in a 13% (AC off) and 15% (AC on) improvement in overall fuel economy.
Recommended Content
Technical Paper | Impact of Auxiliary Loads on Fuel Economy and Emissions in Transit Bus Applications |
Technical Paper | Hybrid Electric Transit Bus |
Authors
Topic
Citation
Campbell, J., Watts, W., and Kittelson, D., "Reduction of Accessory Overdrive and Parasitic Loading on a Parallel Electric Hybrid City Bus," SAE Technical Paper 2012-01-1005, 2012, https://doi.org/10.4271/2012-01-1005.Also In
References
- Kluger, M. Harris, J. “Fuel Economy Benefits of Electric and Hydraulic Off Engine Accessories,” SAE Technical Paper 2007-01-0268 2007 10.4271/2007-01-0268
- Page, R. Hnatczuk, W. Kozierowski, J. “Thermal Management for the 21st Century - Improved Thermal Control & Fuel Economy in an Army Medium Tactical Vehicle,” SAE Technical Paper 2005-01-2068 2005 10.4271/2005-01-2068
- Page, R. Bedogne, R. Steinmetz, T. Bryant, A. “A “Mini-Hybrid” Transit Bus with Electrified Cooling System,” SAE Technical Paper 2006-01-3475 2006 10.4271/2006-01-3475
- Stodolsky, F. Gaines, L. Vyas, A. “Analysis of Technology Options to Reduce the Fuel Consumption of Idling Trucks.” Argonne National Laboratory Argonne, IL 2000
- Grupp, D. Forrest, M. Mader, P. Brodrick, C. et al. “Development of a Retrofit Fuel Cell Auxiliary Power Unit for Truck Idle Reduction,” SAE Technical Paper 2004-01-2629 2004 10.4271/2004-01-2629
- Zizelman, J. Shaffer, S. Mukerjee, S. “Solid Oxide Fuel Cell Auxiliary Power Unit - A Development Update,” SAE Technical Paper 2002-01-0411 2002 10.4271/2002-01-0411
- Brodrick, C. Farshchi, M. Dwyer, H. Gouse, S. et al. “Demonstration of a Proton Exchange Membrane Fuel Cell as an Auxiliary Power Source for Heavy Trucks,” SAE Technical Paper 2000-01-3488 2000 10.4271/2000-01-3488
- Grupp, D. Forrest, M. Mader, P. Brodrick, C. et al. “Development of a Retrofit Fuel Cell Auxiliary Power Unit for Truck Idle Reduction,” SAE Technical Paper 2004-01-2629 2004 10.4271/2004-01-2629
- Surampudi, B. Redfield, J. Ray, G. Montemayor, A. et al. “Electrification and Integration of Accessories on a Class-8 Tractor,” SAE Technical Paper 2005-01-0016 2005 10.4271/2005-01-0016
- Redfield, J. Surampudi, B. Gustavo, R. Montemayor, A. et al. “Accessory Electrification in Class 8 Tractors,” SAE Technical Paper 2006-01-0215 2006 10.4271/2006-01-0215
- Hendricks, T. O'Keefe, M. “Heavy Vehicle Auxiliary Load Electrification for the Essential Power System Program: Benefits, Tradeoffs, and Remaining Challenges,” SAE Technical Paper 2002-01-3135 2002 10.4271/2002-01-3135
- Lutsey, N. Wallace, J. Brodrick, C. Dwyer, H. et al. “Modeling Stationary Power for Heavy-Duty Trucks: Engine Idling vs. Fuel Cell APUs,” SAE Technical Paper 2004-01-1479 2004 10.4271/2004-01-1479
- Conover, J. Husted, H. MacBain, J. McKee, H. “Logistics and Capability Implications of a Bradley Fighting Vehicle with a Fuel Cell Auxiliary Power Unit,” SAE Technical Paper 2004-01-1586 2004 10.4271/2004-01-1586
- Filipi, Z. Louca, L. Stefanopoulou, A. Pukrushpan, J. et al. “Fuel Cell APU for Silent Watch and Mild Electrification of a Medium Tactical Truck,” SAE Technical Paper 2004-01-1477 2004 10.4271/2004-01-1477
- Lim, H. “Study of Exhaust Emissions from Idling Heavy Duty Diesel Trucks and Commercially Available Idle Reducing Devices,” SAE Technical Paper 2003-01-0288 2003 10.4271/2003-01-0288
- American Transportation Research Institute “Compendium of Idling Regulations” June 2008 January 2009 http://atri-online.org/research/idling/atri_idlingcompendium7_11_08.pdf